Kizlon

Kizlon

Share

07/05/2018

Infusion Pump KIP-A100 :
Our Infusion Pump is a portable machine suitable for any brand of disposable IV set and has automatic calibration for IV sets.

Specifications:
Adjustable drop rate range:

1~400 drops/min (1 drop/min increment)

Infusion volume range:

1 ml~9999.9ml ( 0.1ml increment)

Maximum Accumulated Volume:

9999.9 ml ( 0.1ml increment)

Adjustable Infusion Volume Rate Range:

1.0~99.9ml/h (0.1ml/h increment) 100~1200ml/h (1ml/h increment)

Flow rate precision:

Within±3% (using the IV set appointed by the manufacturer or calibrated high quality IV set)

Mechanical precision:

Within±2%

Purge and Bolus rate:

Purge rate: 800 ml/h Bolus rate: adjustable from 10~1200ml/h, in steps of 0.1ml/h (flow rate 100ml/h)

KVO Rate:

1 ml/h (1~300ml/h); 3ml/h (greater than 300 ml/h)

Time Range:

1 min~9999 min ( 1 min increment)

Occlusion Alarm Threshold:

High: 800 mmHg±200 mmHg (106.7kPa±26.7kPa) Medium: 500 mmHg±100 mmHg (66.7kPa±13.3kPa) Low: 300 mmHg±100 mmHg (40.7kPa±13.3kPa)

Sensitivity of air bubble detector:

>25μL

Operating temperature:

5~40⁰C

Storage temperature:

-10~55⁰C

Operating humidity:

20~90%

Storage humidity:

10~90%

Fuse:

F1AL/250V ("F" indicate fast, "L" indicate low breaking capacity), 2 pcs (installed inside pump).

Power supply:

AC 85~265V, 50/60Hz, 2000mAh; the pump can work more than 4 hours at the flow rate of 25 ml/h after charging for 8 hours

Dimensions:

125x125x230mm

Weight:

2.2kg

Features:
• The pump has a 4.3” colour TFT LCD screen with LED backlight and resolution of 272X480 and support of multi-language display
• Working mechanism is based on drip type peristaltic pump
• It has 3 working modes of Rate, Time and Volume
• It has a heating function which is suitable for infusing in winter or if there is requirement for the fluid medication temperature
• It has features of Purge and Bolus functions and waterproof class-IPX4
• The pump goes into KVO mode automatically as an infusion is completed
• Three levels of the occlusion limited pressure-high, middle and low
• An air bubble is detected by ultrasonic detector
• It has a drug library with 210 kinds of medicine and storage of 1500 historical records
• 8 hours internal Lithium-ion polymer battery backup
• Alarm functions for Occlusion, empty bottle, low battery, rate error, end of infusion, door open, air in line, mis-operation, setting error, AC power off, Idle etc
• Three levels of alarm sound-high, middle and low

Applications:
Infusion pumps can administer fluids as little as 0.1ml per hour injections (too small for a drip), injections every minute, injections with repeated boluses requested by the patient, up to maximum number per hour (e.g. in patient-controlled analgesia), or fluids whose volumes vary by the time of day.