UL and ETL listing accurate? Lets find out and see if they are doing the best job they can do! In my other video I received comments on why I think a heater would draw what the product listed stated. I wanted to prove that these rating can not be made up, and are tested to ensure they are accurate. In this process I found still more flaws in what they are allowing the USA to have and use. They are the ones in control of what products can be used and they need to ensure people will be able to use them in accordance with the nfpa 70. I'm on a mission to figure why they allow people to be able to make such poor decisions like my wife and me. We almost had a real problem but because of this video I found it early. Thankfully. Do better big business.
80% rule? 1500 watts on a 15 amp outlet! The 80 percent rule is just terrible. It is not the right way of thinking about electrical work. You need to be sizing your circuits based on the intended load, and not what size overcurrent protection you have. For electrical to be safe it has to start with the manufactures. If they make crap all we can do is install crap. It all has to start there. Then any good electrician will install there products as intended. No electrical issues. Crap product crap follows.
I provide this service at no cost to my customers. My only goal is to assure the safety and reliability of there electrical systems. Watch my other videos to learn more about what I do.
www.youtube.com/
https://youtu.be/TKrQNGzMMSQ?si=SyiDsht-lYnPJCIq
https://youtu.be/mrHdCxkuk7Y?si=crQ28PgLUyVOPFv6
#80%rule #125%rule
Has your electrical panel been checked in the last 5 years? It needs to be! Join me in giving a in depth look into what should be completed every 5 years on the electrical panel. This job can only be completed by someone that has the experience of working in many panels over the years. The more experience one has in working with electrical equipment, the more future problems they can resolve before then. I have spent a lot of time doing as they call "dust and cleans" preventive maintenance on high voltage equipment. This work is now required by nec 70b. Here in pa maybe in a year or two. If you are not doing this type of work yet start now. Maintenance companies will be forming over this compliance and maybe you can start one. If not anything more maintenance positions at companies now. This work is critical for the safety of person and equipment.
Are you a electrician? I can tell just by one question! Should I become an electrician. Electrical panel maintenance. Electrician knowledge. Electrical experience. Electrician # Electrical # Label # Spec #